<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Belzona proizvodi i tehnologije popravaka i zaštite u industijama &#187; Energetika</title>
	<atom:link href="http://belzona.hr/category/industrije/energetika/feed/" rel="self" type="application/rss+xml" />
	<link>http://belzona.hr</link>
	<description>popravak, zaštita, poboljšanje i ušteda</description>
	<lastBuildDate>Tue, 10 Apr 2012 12:01:28 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.2</generator>
		<item>
		<title>Popravak curenja transformatora</title>
		<link>http://belzona.hr/aplikacije/popravak-curenja-transformatora/</link>
		<comments>http://belzona.hr/aplikacije/popravak-curenja-transformatora/#comments</comments>
		<pubDate>Thu, 22 Mar 2012 12:08:11 +0000</pubDate>
		<dc:creator>nstrelar</dc:creator>
				<category><![CDATA[Aplikacije]]></category>
		<category><![CDATA[Energetika]]></category>
		<category><![CDATA[Industrije]]></category>
		<category><![CDATA[Transformatori]]></category>
		<category><![CDATA[curenje ulja]]></category>

		<guid isPermaLink="false">http://belzona.hr/?p=2344</guid>
		<description><![CDATA[U siječnju 2012, na elektrani koja se nalazi na sjeveru Francuske, lokalni Belzona Distributer, bio je suočen sa upitom da li bi se moglo zaustaviti curenje ulja koja se dogodilo na prirubnici jednog od transformatora. Za alternativnu zamjenu brtve bilo bi potrebno pražnjenje 42 tona ulja iz transformatora, kao i demontaža pojedinih 70 prirubnica, što bi bilo vrlo dugotrajno. Curenje ulja  nastaje radi erozionaih oštećenja i neispravnih brtvenih spojeva. Ako se ostavi neriješeno, to curenje može dovesti do pogoršanja transformatora, što uzrokuje gubitke ulja, skupe zastoje i štetu za okoliš. Za rješenje problema, površina je prvo pripremljena koristeći MBX ® Blaster alat za ...]]></description>
			<content:encoded><![CDATA[<p><a href="http://belzona.hr/wp-content/uploads/2012/03/emuller_3090_1.jpg"><img class="size-medium wp-image-2349 alignright" title="Curenje uljana  transformatoru 1" src="http://belzona.hr/wp-content/uploads/2012/03/emuller_3090_1-300x225.jpg" alt="Curenje uljana  transformatoru 1" width="300" height="225" /></a>U siječnju 2012, na elektrani koja se nalazi na sjeveru Francuske, lokalni Belzona Distributer, bio je suočen sa upitom da li bi se moglo zaustaviti curenje ulja koja se dogodilo na prirubnici jednog od transformatora.</p>
<p>Za alternativnu zamjenu brtve bilo bi potrebno pražnjenje 42 tona ulja iz transformatora, kao i demontaža pojedinih 70 prirubnica, što bi bilo vrlo dugotrajno.</p>
<p>Curenje ulja  nastaje radi erozionaih oštećenja i neispravnih brtvenih spojeva.</p>
<p>Ako se ostavi neriješeno, to curenje može dovesti do pogoršanja transformatora, što uzrokuje gubitke ulja, skupe zastoje i štetu za okoliš.</p>
<p>Za rješenje problema, površina je prvo pripremljena koristeći MBX ® Blaster alat za hrapavljenje površine i odmašćena.</p>
<p>Nadalje, prvi sloj <a title="Belzona 1831" href="http://belzona.hr/pdf/1831Flyer.pdf" target="_blank">Belzona 1831 (Super UW-Metal)</a> nanijet je na sve prirubnice da spriječi daljnje curenje.</p>
<p><a href="http://belzona.hr/wp-content/uploads/2012/03/emuller_3090_2.jpg"><img class="alignright size-medium wp-image-2350" title="Curenje uljana  transformatoru 2" src="http://belzona.hr/wp-content/uploads/2012/03/emuller_3090_2-300x225.jpg" alt="Curenje uljana  transformatoru 2" width="300" height="225" /></a>Belzona 9341 (Armaturna traka),  umoči se s <a title="Belzona 1831" href="http://belzona.hr/pdf/1831Flyer.pdf" target="_blank">Belzona 1831 (Super UW-Metal)</a>, koja se aplicira na prethodi sloj i zatim prekrivena sa daljnjim slojem <a title="Belzona 1831" href="http://belzona.hr/pdf/1831Flyer.pdf" target="_blank">Belzona 1831 (Super UW-Metal)</a>.</p>
<p>Proizvod se također primijenjuje na neke od vijaka prirubnice, pošto je curenje ulja kroz njih također prisutno.</p>
<p>Cijeli transformator je zatim prebojen sa standardnom bojom.</p>
<p><img class="alignright size-medium wp-image-2351" style="border-style: initial; border-color: initial;" title="Curenje uljana  transformatoru 4" src="http://belzona.hr/wp-content/uploads/2012/03/emuller_3090_4-300x203.jpg" alt="Curenje uljana  transformatoru 4" width="300" height="203" /></p>
<p>Belzona proizvodi odabrani su za ovu primjenu zbog njihove sposobnosti prijanjaja i njihove jaka adhezije na masnu, mokru ili ručno pripremljenu podlogu, oni su idealno rješenje električna postrojenja.<br />
Bitna je i činjenica da je ovaj popravak jeftin za korisnika jer je obavljen u samo dva tjedna, unatoč teškoćama koje stvara konvencionalan pristup ovakvim problemima.</p>
<p>Belzona rješenja omogućuju hladno zatvaranje curenja prirubnica, te ih štite od daljnje korozije.</p>
<p>&nbsp;</p>
<div></div>
]]></content:encoded>
			<wfw:commentRss>http://belzona.hr/aplikacije/popravak-curenja-transformatora/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Zaštita izmjenjivaća topline od bimetalne korozije</title>
		<link>http://belzona.hr/aplikacije/izmjenjivaci-topline/zastita-izmjenjivaca-topline-odo-bimetalne-korozije/</link>
		<comments>http://belzona.hr/aplikacije/izmjenjivaci-topline/zastita-izmjenjivaca-topline-odo-bimetalne-korozije/#comments</comments>
		<pubDate>Fri, 25 Mar 2011 12:35:49 +0000</pubDate>
		<dc:creator>nstrelar</dc:creator>
				<category><![CDATA[Energetika]]></category>
		<category><![CDATA[Izmjenjivači topline]]></category>
		<category><![CDATA[izmjenjivač]]></category>
		<category><![CDATA[korozija]]></category>

		<guid isPermaLink="false">http://belzona.hr/?p=1325</guid>
		<description><![CDATA[TE Plomin. Bimetalna korozija veliki je problem na spoju cijevi metalne ploče, što uzrokuje propuštanje cijevi. Depresije na površini moguće je nadomjestiti Belzonom 1311 metalim i zaštititi Belzona 1321 premazom, čime se ostvaruje izolirana zaštita od bimetane korozije. Bitno je napomenuti kako je ova sanacije izvršena na licu mjesta i uz minimmalan zastoj pogona, čime je korisnik ostvario veliku uštedu. ...]]></description>
			<content:encoded><![CDATA[<p><strong><br />
<h6 class="fancy_header"><span>Fotografija:</span></h6>
<p></strong></p>
<div class="one_half">
<div id="attachment_1326" class="wp-caption alignnone" style="width: 310px"><a href="http://belzona.hr/wp-content/uploads/2011/03/P1050681-e1300967768958.jpg" rel="prettyPhoto"><img class="size-medium wp-image-1326 " title="Oštećenja na izmjenjivaču topline" src="http://belzona.hr/wp-content/uploads/2011/03/P1050681-300x225.jpg" alt="Oštećenja na izmjenjivaču topline" width="300" height="225" /></a>
<p class="wp-caption-text">Oštećenja na izmjenjivaču topline</p>
</div>
</div>
<div class="one_half last">
<div id="attachment_1327" class="wp-caption alignnone" style="width: 310px"><a href="http://belzona.hr/wp-content/uploads/2011/03/P1050734-e1300967739794.jpg" rel="prettyPhoto"><img class="size-medium wp-image-1327  " title="Zaštićeni izmjenjivač topline" src="http://belzona.hr/wp-content/uploads/2011/03/P1050734-300x225.jpg" alt="Zaštićeni izmjenjivač topline" width="300" height="225" /></a>
<p class="wp-caption-text">Zaštićeni izmjenjivač topline</p>
</div>
</div>
<div class="clearboth"></div>
<p><strong><br />
<h6 class="fancy_header"><span>Refernca:</span></h6>
<p></strong> TE Plomin.</p>
<p><strong><br />
<h6 class="fancy_header"><span>Situacija:</span></h6>
<p></strong> Bimetalna korozija veliki je problem na spoju cijevi metalne ploče, što uzrokuje propuštanje cijevi. Depresije na površini moguće je nadomjestiti Belzonom 1311 metalim i zaštititi Belzona 1321 premazom, čime se ostvaruje izolirana zaštita od bimetane korozije. Bitno je napomenuti kako je ova sanacije izvršena na licu mjesta i uz minimmalan zastoj pogona, čime je korisnik ostvario veliku uštedu.<strong> </strong></p>
<p><strong><br />
<h6 class="fancy_header"><span>Proizvodi:</span></h6>
<p></strong> Belzona 1311 i Belzona 1321</p>
]]></content:encoded>
			<wfw:commentRss>http://belzona.hr/aplikacije/izmjenjivaci-topline/zastita-izmjenjivaca-topline-odo-bimetalne-korozije/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Ojačanje metalne oplate spremnika za odsumporavanje</title>
		<link>http://belzona.hr/aplikacije/brtve-spojevi-i-zapune/ojacanje-metalne-oplate-spremnika-za-odsumporavanje/</link>
		<comments>http://belzona.hr/aplikacije/brtve-spojevi-i-zapune/ojacanje-metalne-oplate-spremnika-za-odsumporavanje/#comments</comments>
		<pubDate>Mon, 21 Mar 2011 18:46:08 +0000</pubDate>
		<dc:creator>nstrelar</dc:creator>
				<category><![CDATA[Brtve, spojevi i zapune]]></category>
		<category><![CDATA[Energetika]]></category>
		<category><![CDATA[korozija]]></category>

		<guid isPermaLink="false">http://belzona.hr/?p=1271</guid>
		<description><![CDATA[TE Plomin. Korozija vanjske površine metalne stjenke spremnika narušava debljinu stjenke te može doći do propuštanja procesne tekućine. Belzona tehnologijom &#8220;Plate bonding&#8221; odnosno ljepljenje metalnih ploča, stjenku spremnika moguće je ojačati i zaštititi od korozije. Popravak je obavljen &#8220;in stu&#8221; odnosno pri pogonu postrojenja. Belzona 1111]]></description>
			<content:encoded><![CDATA[<p><strong><br />
<h6 class="fancy_header"><span>Fotografija:</span></h6>
<p></strong></p>
<div class="one_half">
<div id="attachment_1272" class="wp-caption alignnone" style="width: 235px"><a href="http://belzona.hr/wp-content/uploads/2011/03/IMG_1909.jpg" rel="prettyPhoto"><img class="size-medium wp-image-1272 " title="Oštećenje na vanjska stijeni spremnika za odsumporavanje" src="http://belzona.hr/wp-content/uploads/2011/03/IMG_1909-225x300.jpg" alt="Oštećenje na vanjska stijeni spremnika za odsumporavanje" width="225" height="300" /></a>
<p class="wp-caption-text">Oštećenje na vanjska stijeni spremnika za odsumporavanje</p>
</div>
</div>
<div class="one_half last">
<div id="attachment_1273" class="wp-caption alignnone" style="width: 310px"><a href="http://belzona.hr/wp-content/uploads/2011/03/IMG_1921.jpg" rel="prettyPhoto"><img class="size-medium wp-image-1273 " title="Ojačana stijena spremnika za odsumporavanje" src="http://belzona.hr/wp-content/uploads/2011/03/IMG_1921-300x225.jpg" alt="Ojačana stijena spremnika za odsumporavanje" width="300" height="225" /></a>
<p class="wp-caption-text">Ojačana stijena spremnika za odsumporavanje</p>
</div>
</div>
<div class="clearboth"></div>
<p><strong><br />
<h6 class="fancy_header"><span>Refernca:</span></h6>
<p></strong> TE Plomin.</p>
<p><strong><br />
<h6 class="fancy_header"><span>Situacija:</span></h6>
<p></strong> Korozija vanjske površine metalne stjenke spremnika narušava debljinu stjenke te može doći do propuštanja procesne tekućine. Belzona tehnologijom &#8220;Plate bonding&#8221; odnosno ljepljenje metalnih ploča, stjenku spremnika moguće je ojačati i zaštititi od korozije. Popravak je obavljen &#8220;in stu&#8221; odnosno pri pogonu postrojenja.<strong> </strong></p>
<p><strong><br />
<h6 class="fancy_header"><span>Proizvodi:</span></h6>
<p></strong> Belzona 1111</p>
]]></content:encoded>
			<wfw:commentRss>http://belzona.hr/aplikacije/brtve-spojevi-i-zapune/ojacanje-metalne-oplate-spremnika-za-odsumporavanje/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Popravak usisnog zvona oštećenog kavitacijom</title>
		<link>http://belzona.hr/aplikacije/ventili-cijevi-i-fitinzi/poprava-usisnog-zvona-ostecenog-kavitacijom/</link>
		<comments>http://belzona.hr/aplikacije/ventili-cijevi-i-fitinzi/poprava-usisnog-zvona-ostecenog-kavitacijom/#comments</comments>
		<pubDate>Sun, 20 Mar 2011 17:27:09 +0000</pubDate>
		<dc:creator>nstrelar</dc:creator>
				<category><![CDATA[Energetika]]></category>
		<category><![CDATA[Ventili, cijevi i fitinzi]]></category>
		<category><![CDATA[cijev]]></category>
		<category><![CDATA[kavitacija]]></category>
		<category><![CDATA[ljevak]]></category>

		<guid isPermaLink="false">http://belzona.hr/wordpress/?p=1242</guid>
		<description><![CDATA[TETO Zagreb. Ljudska pogreška dovela je do povećanog protoka, jakih vrtlogai visoke kavitacije na unutarnjoj površini usisnog zvona. Belzonom 1311 keramičkim kitom površina se nadograđuje na originalnu mjeru te se Belzonom 1321 keramičkim premazom površina štiti od utjecaja kavitacije, erozije i korozije uz povećanja protoka fluida.  Belzona 1311 i Belzona 1321]]></description>
			<content:encoded><![CDATA[<p><strong><br />
<h6 class="fancy_header"><span>Fotografija:</span></h6>
<p></strong></p>
<div class="one_half">
<div id="attachment_1244" class="wp-caption alignnone" style="width: 310px"><a href="http://belzona.hr/wp-content/uploads/2011/03/inlet05.jpg" rel="prettyPhoto"><img class="size-medium wp-image-1244 " title="Površina kavitacije" src="http://belzona.hr/wp-content/uploads/2011/03/inlet05-300x207.jpg" alt="Površina kavitacije" width="300" height="207" /></a>
<p class="wp-caption-text">Površina kavitacije</p>
</div>
</div>
<div class="one_half last">
<div id="attachment_1245" class="wp-caption alignnone" style="width: 221px"><a href="http://belzona.hr/wp-content/uploads/2011/03/vert7.jpg" rel="prettyPhoto"><img class="size-medium wp-image-1245 " title="Zaštićeno usisno zvono" src="http://belzona.hr/wp-content/uploads/2011/03/vert7-211x300.jpg" alt="Zaštićeno usisno zvono" width="211" height="300" /></a>
<p class="wp-caption-text">Zaštićeno usisno zvono</p>
</div>
</div>
<div class="clearboth"></div>
<p><strong><br />
<h6 class="fancy_header"><span>Refernca:</span></h6>
<p></strong> TETO Zagreb.</p>
<p><strong><br />
<h6 class="fancy_header"><span>Situacija:</span></h6>
<p></strong> Ljudska pogreška dovela je do povećanog protoka, jakih vrtlogai visoke kavitacije na unutarnjoj površini usisnog zvona. Belzonom 1311 keramičkim kitom površina se nadograđuje na originalnu mjeru te se Belzonom 1321 keramičkim premazom površina štiti od utjecaja kavitacije, erozije i korozije uz povećanja protoka fluida. <strong> </strong></p>
<p><strong><br />
<h6 class="fancy_header"><span>Proizvodi:</span></h6>
<p></strong> Belzona 1311 i Belzona 1321</p>
]]></content:encoded>
			<wfw:commentRss>http://belzona.hr/aplikacije/ventili-cijevi-i-fitinzi/poprava-usisnog-zvona-ostecenog-kavitacijom/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Rotor pumpe za otpadne vode</title>
		<link>http://belzona.hr/industrije/protok-fluida/rotor-pumpe-za-otpadne-vode/</link>
		<comments>http://belzona.hr/industrije/protok-fluida/rotor-pumpe-za-otpadne-vode/#comments</comments>
		<pubDate>Sun, 13 Mar 2011 18:55:43 +0000</pubDate>
		<dc:creator>nstrelar</dc:creator>
				<category><![CDATA[Energetika]]></category>
		<category><![CDATA[Protok fluida]]></category>
		<category><![CDATA[Pumpe]]></category>
		<category><![CDATA[Vodovod i odvodnja]]></category>
		<category><![CDATA[erozija]]></category>
		<category><![CDATA[kavitacija]]></category>
		<category><![CDATA[pumpa]]></category>

		<guid isPermaLink="false">http://belzona.hr/wordpress/?p=1127</guid>
		<description><![CDATA[TE Zagreb Rotor oštećen kavitacijom i erozijom otpadnih voda može se u kratkom vremenu obnoviti Belzonom 1311 i Belzonom 1321 te vratiti u pogon što pridonosi odličnoj zaštiti od kavitacije i erozije. Važno je napomenuti da se ovime i povećava efikasnost originalnih karakteristika pumpe. Belzona 1311 i Belzona 1321]]></description>
			<content:encoded><![CDATA[<p><strong><br />
<h6 class="fancy_header"><span></strong><strong>Fotografije:</strong><strong></span></h6>
<p></strong></p>
<div class="one_half">
<p><a rel="prettyPhoto" href="http://belzona.hr/wp-content/uploads/2011/03/P9260005.jpg"><img class="size-medium wp-image-1128  alignnone" title="Erozija i kavitacija impelera pumpe" src="http://belzona.hr/wp-content/uploads/2011/03/P9260005-225x300.jpg" alt="Erozija i kavitacija impelera pumpe" /></a></p>
</div>
<div class="one_half last">
<p><a rel="prettyPhoto" href="http://belzona.hr/wp-content/uploads/2011/03/PA030021.jpg"><img class="size-medium wp-image-1129  alignnone" title="Zaštićen rotor pumpe" src="http://belzona.hr/wp-content/uploads/2011/03/PA030021-225x300.jpg" alt="Zaštićen rotor pumpe" /></a></p>
</div>
<div class="clearboth"></div>
<p><strong></strong><strong><br />
<h6 class="fancy_header"><span>Refernca:</span></h6>
<p></strong> TE Zagreb</p>
<p><strong><br />
<h6 class="fancy_header"><span>Situacija:</span></h6>
<p></strong> Rotor oštećen kavitacijom i erozijom otpadnih voda može se u kratkom vremenu obnoviti Belzonom 1311 i Belzonom 1321 te vratiti u pogon što  pridonosi odličnoj zaštiti od kavitacije i erozije. Važno je napomenuti da se ovime i povećava efikasnost originalnih karakteristika pumpe.</p>
<p><strong><br />
<h6 class="fancy_header"><span>Proizvodi:</span></h6>
<p></strong> Belzona 1311 i Belzona 1321</p>
]]></content:encoded>
			<wfw:commentRss>http://belzona.hr/industrije/protok-fluida/rotor-pumpe-za-otpadne-vode/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Zaštita cjevovoda rashladne morske vode</title>
		<link>http://belzona.hr/industrije/protok-fluida/zastita-cjevovoda-rashladne-morske-vode/</link>
		<comments>http://belzona.hr/industrije/protok-fluida/zastita-cjevovoda-rashladne-morske-vode/#comments</comments>
		<pubDate>Tue, 08 Mar 2011 10:19:12 +0000</pubDate>
		<dc:creator>nstrelar</dc:creator>
				<category><![CDATA[Energetika]]></category>
		<category><![CDATA[Protok fluida]]></category>
		<category><![CDATA[Ventili, cijevi i fitinzi]]></category>
		<category><![CDATA[cijev]]></category>
		<category><![CDATA[korozija]]></category>

		<guid isPermaLink="false">http://belzona.hr/wordpress/?p=937</guid>
		<description><![CDATA[TE Plomin Slana morska voda i organizmi koji u njoj žive oštetili su cjevovod do zabrinjavajuće debljine stjenke cjevovoda. Unutarnja površina cjevovoda pripremljena je pjeskarenjem, odmašćena i zaštićena u dva sloja s Belzonom 5811 koja je otporna na sastav morske vode. Belzona 5811]]></description>
			<content:encoded><![CDATA[<p><strong><br />
<h6 class="fancy_header"><span></strong><strong>Fotografije:</strong><strong></span></h6>
<p></strong></p>
<div class="one_half"><strong></strong><strong></strong></p>
<p><a rel="prettyPhoto" href="http://belzona.hr/wp-content/uploads/2011/03/IMGP0220.jpg"><img class="size-medium wp-image-938  alignnone" title="Oštećeni cjevovod rashladne morske vode" src="http://belzona.hr/wp-content/uploads/2011/03/IMGP0220-225x300.jpg" alt="Oštećeni cjevovod rashladne morske vode" /></a></p>
</div>
<div class="one_half last"><strong></strong></p>
<p><a rel="prettyPhoto" href="http://belzona.hr/wp-content/uploads/2011/03/P1010077.jpg"><img class="size-medium wp-image-939  alignnone" title="Zaštićeni cjevovod rashladne morske vode" src="http://belzona.hr/wp-content/uploads/2011/03/P1010077-300x225.jpg" alt="Zaštićeni cjevovod rashladne morske vode" /></a></p>
</div>
<div class="clearboth"></div>
<p><strong></strong></p>
<p><strong></strong><strong><br />
<h6 class="fancy_header"><span>Refernca:</span></h6>
<p></strong> TE Plomin</p>
<p><strong><br />
<h6 class="fancy_header"><span>Situacija:</span></h6>
<p></strong> Slana morska voda i organizmi koji u njoj žive oštetili su cjevovod do zabrinjavajuće  debljine stjenke cjevovoda. Unutarnja površina cjevovoda pripremljena je pjeskarenjem, odmašćena i zaštićena u dva sloja s Belzonom 5811 koja je otporna na sastav morske vode.</p>
<p><strong><br />
<h6 class="fancy_header"><span>Proizvodi:</span></h6>
<p></strong> Belzona 5811</p>
]]></content:encoded>
			<wfw:commentRss>http://belzona.hr/industrije/protok-fluida/zastita-cjevovoda-rashladne-morske-vode/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Zaštita od abrazije koljena cijevi za transport ugljene prašine</title>
		<link>http://belzona.hr/aplikacije/ventili-cijevi-i-fitinzi/zastita-od-abrazije-starih-koljena-cijevi-za-prenos-ugljene-prasine/</link>
		<comments>http://belzona.hr/aplikacije/ventili-cijevi-i-fitinzi/zastita-od-abrazije-starih-koljena-cijevi-za-prenos-ugljene-prasine/#comments</comments>
		<pubDate>Mon, 28 Feb 2011 10:40:45 +0000</pubDate>
		<dc:creator>nstrelar</dc:creator>
				<category><![CDATA[Energetika]]></category>
		<category><![CDATA[Ventili, cijevi i fitinzi]]></category>
		<category><![CDATA[abrazija]]></category>
		<category><![CDATA[cijev]]></category>

		<guid isPermaLink="false">http://belzona.hr/?p=746</guid>
		<description><![CDATA[TE Plomin Belzona premaz protiv abrazije pridonosi duljem vijeku trajanja opreme i smanjenju troškova zamjenskih dijelova, pogotovo na dijelovima pod utjecajem jakih udara ugljene prašine kao što su koljena cijevi za prijenos ugljene prašine. Belzona 1812]]></description>
			<content:encoded><![CDATA[<p><strong><br />
<h6 class="fancy_header"><span></strong><strong>Fotografije:</strong><strong></span></h6>
<p></strong></p>
<div class="one_half"><strong></strong><strong></strong></p>
<p><a rel="prettyPhoto" href="http://belzona.hr/wp-content/uploads/2011/02/P1040743-e1298923126856.jpg"><img class="size-medium wp-image-748   alignnone" title="Oštećenje na koljenu cjevovoda za prijenos ugljene prašine" src="http://belzona.hr/wp-content/uploads/2011/02/P1040743-300x225.jpg" alt="Oštećenje na koljenu cjevovoda za prijenos ugljene prašine" /></a></p>
</div>
<div class="one_half last"><strong></strong></p>
<p><a rel="prettyPhoto" href="http://belzona.hr/wp-content/uploads/2011/02/P1040753-e1298923089666.jpg"><img class="size-medium wp-image-749   alignnone" title="Sanacija oštećenja koljena cjevovoda" src="http://belzona.hr/wp-content/uploads/2011/02/P1040753-300x225.jpg" alt="Sanacija oštećenja koljena cjevovoda" /></a></p>
</div>
<div class="clearboth"></div>
<p><strong></strong></p>
<p><strong></strong><strong><br />
<h6 class="fancy_header"><span>Refernca:</span></h6>
<p></strong> TE Plomin</p>
<p><strong><br />
<h6 class="fancy_header"><span>Situacija:</span></h6>
<p></strong> Belzona premaz protiv abrazije pridonosi duljem vijeku trajanja opreme i smanjenju troškova zamjenskih dijelova, pogotovo na dijelovima pod utjecajem jakih udara ugljene prašine kao što su koljena cijevi za prijenos ugljene prašine.</p>
<p><strong><br />
<h6 class="fancy_header"><span>Proizvodi:</span></h6>
<p></strong> Belzona 1812</p>
]]></content:encoded>
			<wfw:commentRss>http://belzona.hr/aplikacije/ventili-cijevi-i-fitinzi/zastita-od-abrazije-starih-koljena-cijevi-za-prenos-ugljene-prasine/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Zaštita od abrazije ljevka za prjenos pepela</title>
		<link>http://belzona.hr/aplikacije/oprema-za-prijenos-krutih-tvari/zastita-ljevka-za-prjenos-pepela-od-abrazije/</link>
		<comments>http://belzona.hr/aplikacije/oprema-za-prijenos-krutih-tvari/zastita-ljevka-za-prjenos-pepela-od-abrazije/#comments</comments>
		<pubDate>Thu, 24 Feb 2011 13:45:50 +0000</pubDate>
		<dc:creator>nstrelar</dc:creator>
				<category><![CDATA[Energetika]]></category>
		<category><![CDATA[Oprema za prijenos krutih tvari]]></category>
		<category><![CDATA[abrazija]]></category>
		<category><![CDATA[ljevak]]></category>

		<guid isPermaLink="false">http://belzona.hr/?p=742</guid>
		<description><![CDATA[TE Plomin Ljevak za prijenos pepela najčešće napada abrazija što smanjuje debljinu stjenke. Belzona tehnologija zaštite od abrazije materijalom tvrdoće mjerljive sa bazaltom, dugotrajno je i ekonomično riješenje. Belzona 1812]]></description>
			<content:encoded><![CDATA[<p><strong><br />
<h6 class="fancy_header"><span></strong><strong>Fotografije:</strong><strong></span></h6>
<p></strong></p>
<div class="one_half">
<p><a rel="prettyPhoto" href="http://belzona.hr/wp-content/uploads/2011/02/IMGP0077-e1298922891427.jpg"><img class="size-medium wp-image-783  alignnone" title="Ljevak smanjene debljine stjenke" src="http://belzona.hr/wp-content/uploads/2011/02/IMGP0077-300x225.jpg" alt="Ljevak smanjene debljine stjenke" /></a></p>
</div>
<p><strong> </strong></p>
<div class="one_half last">
<p><a rel="prettyPhoto" href="http://belzona.hr/wp-content/uploads/2011/02/IMGP0082-e1298922796614.jpg"><img class="size-medium wp-image-784   alignnone" title="Zaštičeni ljevak" src="http://belzona.hr/wp-content/uploads/2011/02/IMGP0082-300x225.jpg" alt="Zaštičeni ljevak" /></a></p>
</div>
<div class="clearboth"></div>
<p><strong><br />
</strong></p>
<p><strong><br />
<h6 class="fancy_header"><span></strong><strong>Refernca:</strong><strong></span></h6>
<p></strong> TE Plomin</p>
<p><strong><br />
<h6 class="fancy_header"><span></strong><strong>Situacija:</strong><strong></span></h6>
<p></strong> Ljevak za prijenos pepela najčešće napada abrazija što smanjuje debljinu stjenke. Belzona tehnologija zaštite  od abrazije materijalom tvrdoće mjerljive sa bazaltom, dugotrajno je i ekonomično riješenje.</p>
<p><strong><br />
<h6 class="fancy_header"><span></strong><strong>Proizvodi:</strong><strong></span></h6>
<p></strong> Belzona 1812</p>
<p><strong><br />
</strong><strong> </strong></p>
]]></content:encoded>
			<wfw:commentRss>http://belzona.hr/aplikacije/oprema-za-prijenos-krutih-tvari/zastita-ljevka-za-prjenos-pepela-od-abrazije/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Zaštita i povečanje efikasnosti pumpe rashladne morske vode</title>
		<link>http://belzona.hr/industrije/protok-fluida/zastita-pumpe-rashladne-morske-vode/</link>
		<comments>http://belzona.hr/industrije/protok-fluida/zastita-pumpe-rashladne-morske-vode/#comments</comments>
		<pubDate>Thu, 24 Feb 2011 13:30:37 +0000</pubDate>
		<dc:creator>nstrelar</dc:creator>
				<category><![CDATA[Energetika]]></category>
		<category><![CDATA[Protok fluida]]></category>
		<category><![CDATA[Pumpe]]></category>
		<category><![CDATA[korozija]]></category>
		<category><![CDATA[pumpa]]></category>

		<guid isPermaLink="false">http://belzona.hr/?p=736</guid>
		<description><![CDATA[TE Plomin Pumpa rashladne vode tokom 30 g. rada vidljivo je oštećena napadima korozije i erozije morske vode. Belzonom 1311 nadograđuje se oštećena površina, a Belzona 1321 pruža premaz otporan na koroziju i eroziju, te povećava protok fluida i smanjuje utrošak el. energije (učinkoitost je 7% veća od originalnih karakteristika pumpe). Belzona 1311, Belzona 1321]]></description>
			<content:encoded><![CDATA[<p><strong><br />
<h6 class="fancy_header"><span>Fotografije:</span></h6>
<p></strong></p>
<div class="one_half">
<p><a rel="prettyPhoto" href="http://belzona.hr/wp-content/uploads/2011/02/P1010738-e1298922940784.jpg"><img class="size-medium wp-image-779   alignnone" title="Oštećena površina pumpe" src="http://belzona.hr/wp-content/uploads/2011/02/P1010738-300x225.jpg" alt="Oštećena površina pumpe" /></a></p>
</div>
<div class="one_half last">
<p><a rel="prettyPhoto" href="http://belzona.hr/wp-content/uploads/2011/02/P1010870-e1298922914350.jpg"><img class="size-medium wp-image-780   alignnone" title="Zaštićena površina pumpe" src="http://belzona.hr/wp-content/uploads/2011/02/P1010870-300x225.jpg" alt="Zaštićena površina pumpe" /></a></p>
</div>
<div class="clearboth"></div>
<p><strong><br />
<h6 class="fancy_header"><span>Refernca:</span></h6>
<p></strong> TE Plomin</p>
<p><strong><br />
<h6 class="fancy_header"><span>Situacija:</span></h6>
<p></strong> Pumpa rashladne vode tokom 30 g. rada vidljivo je  oštećena napadima korozije i erozije morske vode. Belzonom 1311  nadograđuje se oštećena površina, a Belzona 1321 pruža premaz otporan na koroziju i  eroziju, te povećava protok fluida i smanjuje utrošak el. energije (<span style="text-decoration: underline;">učinkoitost je 7% veća od originalnih karakteristika pumpe).</span></p>
<p><strong><br />
<h6 class="fancy_header"><span>Proizvod:</span></h6>
<p></strong> Belzona 1311, Belzona 1321</p>
]]></content:encoded>
			<wfw:commentRss>http://belzona.hr/industrije/protok-fluida/zastita-pumpe-rashladne-morske-vode/feed/</wfw:commentRss>